Publish Time: 2025-03-07 Origin: Site
1. Veneer beat sensor (proximity switch) |
①Adjust the distance of veneer beat sensor and veneer beat device,0.5cm, the sensor light just bright! ②The sensor‘s insulating spacer just touch the bearing house |
2. Adjust veneer arrive Sensor’s effective range |
① Put a veneer 5-6cm from the above sensor ,check its light bright or not ② If sensor light not bright , adjust the sensor’s reach range as following . |
3. ①Power on ,put a veneer on front of 1# conveyor ,check the time difference between veneer pass the Air way and the veneer beating strip push .②if the veneer beating strip push after whole veneer enter air way ,its okay. if not enter completely but push out ,please adjust “Grade A stack delayed" |
|
4. Adjust Fan power |
①Fan power need be adjust according veneer thickness and moisture. ②If veneer cant be absorbed on the Air way , Increase Fan power |
welcome contact our engineer for help ! |
serenda@prsplywoodmachine.com 0086-15588058177 |